Capacitive level switch
ER-KAPS
Capacitive electrode for level signalling in silos and tanks, for conductive and non-conductive media. Versions are available for temperatures from −20 to 800 °C and pressure up to 20 bar.
- For conductive and non-conductive media
- Temperature up to 800 °C, depending on version
- Aluminium housing, IP 65
- Output: relay 250 VAC or NPN 100 mA
- Power supply 230 VAC ± 10 % or 16–24 VDC
- Sensitivity 10 pF, optionally 20 or 40 pF
Description
ER-KAPS signals the level in silos and tanks on the basis of the capacitive effect. While the tank is empty, the electrode is surrounded by air with a permittivity of 1. When the medium reaches the electrode, the permittivity and capacitance increase and a relay switches on, signalling that the level has been reached.
The probe is made of SUS 304/316, PTFE or UPE, with insulation of UPE, PTFE or ceramic. Connections are from 3/4" to 6", in BSP, NPT or PN 16 versions.
Versions:
- standard
- for high temperatures
- anti-corrosion
- on a rope, for deep tanks
- plate type, for the tank bottom
- for explosive atmospheres
- antistatic
Technical data
| Type | Standard type For high temperatures Anti-corrosion type On a rope (for deep tanks) Plate type for the tank bottom For explosive atmospheres Antistatic type |
|---|---|
| Temperature | -20 to 60*C -20 to 80 *C -20 to 120 *C -20 to 200 *C -20 to 800 *C |
| Pressure | ATM, 20 bar |
| Power supply | 230 Vac * 10% 16 - 24 Vdc |
| Housing | Aluminium IP65 |
| Connection | 3/4" G and NPT, 1", 1 1/2", 2", 3", 4", 5", 6" |
| Connection type | BSP, NPT, PN 16 |
| Output | Relay with 250 Vac NPN 100 mA |
| Probe material | SUS 304/316 PTFE UPE |
| Insulating material | UPE PTFE CERAMIC |
| Sensitivity | 10 pF (standard) 20 pF, 40 pF (option) |
Application examples
Documentation
01Technical documentation1
02Wiring diagrams and examples1
Help with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection