Skip to content
Name, type or catalogue number

    Popular searches

    ↑↓ selectEnter open/ search from any page

    • MPRV

    Relative humidity transmitter

    MPRV

    Transmitter converting relative humidity into a standard 4–20 mA current signal, loop-powered. Version K1 measures 10–90 % RH up to 80 °C, and K2 0–100 % RH at temperatures from −40 to 180 °C.

    Price from120,00 €+ VAT

    Catalogue number Versions
    Send an enquiry for this product
    • MPRV-K1: 10–90 % RH, sensor 0–85 °C, class 4 % + 0.2 %/K
    • MPRV-K2: 0–100 % RH, sensor −40 to 180 °C, class 2 % + 0.1 %/K
    • Output 4–20 mA two-wire, power supply 12–30 V
    • MPRV-K2 to order with 0–20 mA or 0–10 V, four-wire
    • Housing 100 × 100 × 58 mm, IP 65
    • Wall or duct mounting

    Description

    MPRV converts relative humidity into a standard current signal. The measuring range is 10–90 % RH (0–80 °C) or 0–100 % RH (−40 to 180 °C), depending on the version.

    It is used in industrial plants and chambers where the current humidity in the space has to be controlled or monitored, most often in chambers for meat, fruit and vegetables and in incubators.

    Technical data

    Version comparison — swipe the table sideways on a phone.

    PropertyMPRV-K1MPRV-K2
    VersionUP TO 80 ºCUp to 180 ºC
    MountingWall mounting
    Duct mounting
    Wall mounting
    Duct mounting
    Dimensions100x100x58 IP 65100x100x58 IP 65
    InputHumidityHumidity
    Operating temperature0-85 ºC for sensor
    0-60 ºC for electronics
    -40 to +180 ºC for sensor
    0-60 ºC for electronics
    Measuring range10-90 % rel. humidity0-100 % rel. humidity
    Output4-20 mA two-wire / 0-100 % rel. humidity4-20 mA two-wire / 0-100 % rel. humidity
    0-20 mA, 0-10V four-wire / 0-100% rel. humidity [to order only]
    Class4% +0.2%/K2% + 0.1%/K
    Power supply12-30 V, 4-20 mA12-30 V, 4-20 mA

    Dimensions

    The drawings are taken from the technical documentation.

    Documentation

    Help with selection

    Describe your application and we will suggest a version and a catalogue number.

    For an accurate reply, please state in your enquiry:

    1. 01The medium and its temperature
    2. 02Measuring range
    3. 03Output signal or power supply
    4. 04Type of mounting and connection
    Enquiry forMPRVCat. no. 14
    Send an enquiry

    or contact us directly

    Mon – Fri, 7 am – 3 pm