Digital indicator with alarm outputs and data logger
EDPS
Indicator with alarm outputs with one universal analogue input, two or four output relays and an optional continuous output. It stores measurements on a USB stick or SD card and communicates with a computer via Modbus.
- Universal, software-configurable input
- 2 or 4 output relays, ON/OFF control
- Optional continuous output 0/4–20 mA or 0/2–10 V
- Logging of measurements to a USB stick or SD card
- Modbus RS-485 communication
- Accuracy 0.25 % + 2 digits
Why EDPS
- 01
Data logger to USB or SD
Measured values of the analogue inputs and outputs and the states of the digital inputs and outputs are saved to a USB stick or SD card, at an interval you set yourself.
- 02
One input for all signals
Current and voltage signals, thermocouples L, J, K, S, R, T, N, E, B, and Pt100–Pt1000, Ni100–Ni1000, Cu53 and a potentiometer. Cold-junction and lead resistance compensation is built in.
- 03
Housing to suit the mounting location
DIN housings from 48 × 48 to 144 × 72 mm for panel mounting, a DIN-rail version 105 × 90 mm and a wall-mounted housing 160 × 190 × 120 mm.
Description
EDPS has one analogue input. The signal can be a standard current signal (0–20 mA, 4–20 mA), a voltage signal, a signal from a thermocouple (Fe-CuNi – J, Ni-CrNi – K, PtRh-Pt – S and others) or from a Pt100 resistance temperature probe. Cold-junction compensation is provided for thermocouples, and lead resistance compensation for resistance probes.
Control, i.e. signalling, operates via two output relays, so ON/OFF control can be applied. It is also made with four relays. If required, a continuous output is fitted (0/4–20 mA, 0/2–10 V). The measured value is shown on a 4- or 5-digit LED display, alongside a 3-digit display for the unit of measurement.
The measured values of the analogue inputs and outputs and the states of the digital inputs and outputs are stored on a USB stick or SD card (data logger). The storage interval is adjustable. The device communicates with a computer via RS-485 with the Modbus protocol.
It is supplied in DIN housings 96 × 96, 96 × 48, 48 × 96, 48 × 48, 144 × 72, 72 × 144 and 72 × 72 mm, in a DIN-rail version 105 × 90 mm and in a wall-mounted housing 160 × 190 × 120 mm. Power supply is 230 VAC, 110 VAC, 24 VAC or 24 VDC.
Technical data
| Type | EDPS |
|---|---|
| Front panel | Membrane with keypad |
| Mounting | Panel mounting with cut-out |
| Housing | 96x96 mm 96x48 mm 48x96 mm 48x48 mm 144x72 mm 72x144 mm 72x72 mm 105 x 90 mm DIN rail 160x190x120 mm Wall-mounted housing |
| Power supply | 230 VAC 24 VDC 24 VAC 110 VAC |
| Display | 13mm red LED display, 4 or 5 digits + 3-digit display for the unit of measurement |
| Input | Universal - software configurable Current: 0/4 -20 mA / 4-20mA / 20-0 mA / 20-4mA Voltage: 0-50mV / 0-60 mV Thermocouples: L, J, K, S, R, T, N, E, B Resistance: Pt100/200/500/1000, Ni100/200/500/1000, Cu53, potentiometers Other: (PWM signal, frequency) on special request |
| Output | 2 or 4 output relays |
| Alarm | 2 alarms + 2 alarms (optional) |
| Function | Indicating and alarm device OFF/ON |
| Accuracy | 0.25% + 2 digits |
| Communication | Modbus485 USB / SD Card |
Application examples
Documentation
01Technical documentation1
From the same category
Indicators and alarm unitsHelp with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection