Differential dosing scale
DC-DV
Differential scale for dosing bulk and powdered materials, including aggressive and abrasive ones, with a dosing accuracy of ±0.5 %. The dosing system is closed, so there is no dust in the dosing area.
- Dosing accuracy ±0.5 %
- Linear dosing (m³/h) over the whole 0–100 % range
- Dosing of aggressive and abrasive materials
- Closed dosing system, dust-free
- Control by 4–20 mA signal, 0–10 VDC signal or communication
- Developed and manufactured at Elektron
Why DC-DV
- 01
Accuracy ±0.5 %
Dosing in m³/h is linear over the whole range from 0 to 100 %. The control unit automatically corrects the dosing error and linearises dosing according to the material.
- 02
Closed system
The material is dosed in a closed system, with no dust in the dosing area. The scale is also suitable for aggressive and abrasive materials.
- 03
Control from a higher-level system
The higher-level system sets the current flow by a 4–20 mA signal, 0–10 VDC signal or communication, and the scale immediately changes the flow as required.
Description
DC-DV is a dosing scale for bulk and powdered materials. It is also suitable for aggressive and abrasive materials. The dosing system is closed, so there is no dust in the dosing area.
Material dosing (m³/h) is linear over the whole dosing range, from 0 to 100 %. Dosing accuracy is ±0.5 %.
The higher-level system determines the current material flow through the scale, and the scale immediately changes the flow as required. The scale is controlled by a 4–20 mA signal, 0–10 VDC signal or communication.
The scale control unit allows:
- adjustment of the scale to the material being dosed
- automatic correction according to the dosing error
- linearisation of dosing according to the material
The scale is developed entirely at Elektron, so we can adapt its functionality and appearance to the customer’s requirements.
Documentation
01Technical documentation1
From the same category
Scales and dosingHelp with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection