Skip to content
Name, type or catalogue number

    Popular searches

    ↑↓ selectEnter open/ search from any page

    • VR06

    Paperless recorder

    VR06

    Paperless recorder with one to six configurable universal inputs and a 6.4" TFT display with 640 × 480 resolution. It stores data in the 8 MB internal memory and on a card, and communicates with a PC via Ethernet or RS-232/485.

    Price from1.270,00 €+ VAT

    Catalogue number NUMBER OF ANALOGUE INPUTS
    Send an enquiry for this product
    • 6.4" colour TFT LCD, 640 × 480 pixels
    • 1–6 universal analogue inputs
    • 6 relay outputs 5 A / 240 VAC
    • Ethernet (Modbus TCP), optional RS-232/485 (Modbus RTU)
    • Five display modes for current data
    • Housing 144 × 144 mm for panel mounting

    Why VR06

    • 01

      Universal inputs

      Thermocouples J, K, T, E, B, R, S, N and L, Pt100 and mV, mA and 0–1, 0–5, 1–5 and 0–10 V signals, configurable on each of up to six channels.

    • 02

      Five display modes

      Up to six real-time graphs, horizontal or vertical, bargraphs and numeric values alongside the graphs, alarm screen and memory status.

    • 03

      Ethernet and Modbus

      Ethernet with the Modbus TCP protocol is built in as standard. The optional CM181 module adds RS-232 or RS-485/422 with Modbus RTU, up to 247 devices.

    Description

    VR06 is a paperless recorder with a 6.4" display, resolution 640 × 480 (true VGA), an infrared detector, six channels and plug & play I/O cards. It is used for monitoring, recording and evaluating processes in plants.

    It is applied in chemical plants, food and beverage production, petrochemicals, the metal industry, the automotive industry, environmental monitoring and laboratories.

    An Ethernet port is built in as standard; RS-232/485 is an option. Data is transferred to a PC by card or communication. The Observer I software for viewing and saving data comes with the recorder, and real-time viewing is provided by the additional Observer II software.

    Display modes:

    • five display modes for current data
    • six real-time graphs, horizontal or vertical
    • bargraph and numeric values combined with graphs
    • alarm screen and memory status
    • simple change of screen layout

    Internal memory is 8 MB, card memory 512 MB or 1 GB. Power supply is 90–250 VAC or 11–18, 18–36 or 36–72 VDC, 30 W maximum. Operating temperature is 5 to 50 °C at a humidity of 20 to 80 % RH, non-condensing. Protection is IP30 for the front panel and IP20 for the housing.

    Technical data

    TypeVR06
    MountingPanel with cut-out
    Housing144x144 mm
    Power supply90-250VAC, 60VA, 30W maximum
    11-18, 18-36 or 36-72 VDC 60VA, 30W maximum
    Display6.4'' TFT LCD, 640x480 pixel resolution, 256 colours
    Analogue inputstype J -120ºC-1000ºC +/- 1ºC
    type K -200ºC-1370ºC +/-1ºC
    type T -250ºC-400ºC +/-1ºC
    type E -100ºC-900ºC +/-1ºC
    type B 0ºC-1820ºC +/-2ºC
    type R 0ºC-1767.8ºC +/-2ºC
    type S 0ºC-1767.8ºC +/-2ºC
    type N -250ºC-1300ºC +/-1ºC
    type L -200ºC-900ºC +/-1ºC
    PT100 -210ºC-700ºC
    PT100 -200ºC-600ºC
    mV -8mV-70mV
    mA -3mA-27mA
    0-1V -0.12V-1.15V
    0-5V -1.3V-11.5V
    1-5V -1.3V-11.5V
    0-10V -1.3V-11.5V
    Analogue outputsOutput signal: 4-20mA, 0-20mA
    0-5V, 1-5V, 0-10V
    Digital inputsL06"0"- -5V to 0.8V
    L06"1"- 2V to 5V
    Digital outputs6 channels
    N.O contact (form A)
    relay 5A/240 VAC
    MemoryInternal- 8MB, cards- 512MB, 1GB
    Communication1. Standard Ethernet communication
    Protocol: Mod Bus TCP / IP BaseT, wrong-polarity correction for 10 BaseT
    2. COMM module (CM181)
    RS-232 (1 device), RS-485 or RS-422 (up to 247 devices)
    Protocol: Modbus protocol RTU mode
    Address: 1-247
    Operating conditionsOperating temperature: 5ºC to 50ºC
    Humidity: 20 to 80% RH (non-condensing)
    ProtectionIP30- Front panel
    IP20- Housing

    Application examples

    Help with selection

    Describe your application and we will suggest a version and a catalogue number.

    For an accurate reply, please state in your enquiry:

    1. 01The medium and its temperature
    2. 02Measuring range
    3. 03Output signal or power supply
    4. 04Type of mounting and connection
    Enquiry forVR06Cat. no. EVR6.
    Send an enquiry

    or contact us directly

    Mon – Fri, 7 am – 3 pm