Microprocessor PID controller with programmer
PROG-08
On-off or three-position PID controller that runs the process along a set curve: 8 programs of 16 segments, with a start delay for each program. It can also operate as an ordinary controller with a fixed setpoint.
- 8 programs of 16 segments, adjustable start delay
- Operation as a programmer or as a controller with a fixed setpoint
- Up to 4 inputs, 2 or 4 relays 250 V / 5 A
- Optional continuous output 0/4–20 mA or 0/2–10 V
- Modbus RTU / RS-485 and logging to USB or SD (3k version)
- Audible signalling of program status
Why PROG-08
- 01
8 programs of 16 segments
The process is run along a pre-entered curve. For each program you also set a start delay.
- 02
Program status at a glance
Alongside the measured value, the program and segment, the current ramp setpoint, the remaining segment time and the energy consumption in kWh are shown.
- 03
Data logger to USB or SD
The measured values of the analogue inputs and outputs and the states of the digital inputs and outputs are stored at an interval you set yourself.
Description
PROG-08 is a microprocessor on-off and three-position PID controller with programmer. It is used in glass, plastics and ceramics processing, in the chemical and food industries, boiler construction, mechanical engineering, heating and cooling technology and wherever a measured quantity has to be controlled along a defined curve.
The programmer runs the process along a segment curve entered in one of the programs. 8 independent programs of 16 segments are available, and a start delay can be set for each program. The device can also operate as an ordinary on-off or three-position PID controller at a fixed setpoint.
The controller has a maximum of four inputs. The first is a universal analogue input, software-configurable, for all thermocouples covered by the ITS-90 standard, standard current and voltage signals and a Pt100 sensor. The second and third are 0/4–20 mA current inputs, and the fourth is for a potentiometer, e.g. feedback from a valve.
At the output there are two or four relays, for control and alarms. The optional continuous output provides a standard current or voltage signal, and the measured value or the manipulated variable can be assigned to it.
Two four-digit displays show the measured value and the running program and segment, and LEDs show the relay states. During a program, the current ramp setpoint, the remaining segment time, the manipulated variable and the total energy consumption in kWh can be displayed for information.
The device also signals program states, e.g. start, stop and hold, audibly, with a different signal pattern for each state.
The measured values of the analogue inputs and outputs and the states of the digital inputs and outputs are stored on a USB stick or SD card. The logging interval is adjustable.
Technical data
Version comparison — swipe the table sideways on a phone.
| Property | PROG-08 3k | PROG-08 2k |
|---|---|---|
| Front panel | Membrane keypad | Membrane keypad |
| Mounting | Panel with cut-out | Panel with cut-out |
| Housing | 96x96 mm 96x48 mm 48x96 mm | 96x96 mm 96x48 mm 48x96 mm |
| Power supply | 230 V~, 5 Hz | 230 V~, 5 Hz |
| Class | 0.3 + 2 digit | 0.3 + 2 digit |
| Display | 13 mm red LED display, 4 digits, for the measured value 13mm green LED display, 4 digits, for the setpoint | 13 mm red LED display, 4 digits, for the measured value 13mm green LED display, 4 digits, for the setpoint |
| Input | Universal - software configurable Current: 0-20mA, 4-20mA Voltage: 0-2-10 V Thermocouples: L,J, K, N, E, S, R, T, B Resistance: Pt100 On special request: PWM signal, frequency | Universal, software-configurable (Pt100, thermocouples L, J, K, S, R, T, N, E, B, CURRENT: 0/4-20 mA , VOLTAGE: 0/2-10 V , psychrometer, delta Pt100) |
| Programmer | 8 programs x 16 segments | 8 programs x 16 segments |
| Output | 4 relays, 250 VAC / 5 A 0-4-20 mA continuous output (optional) 0-2-10 V continuous output (optional) | 2 relays, 250 VAC / 5 A |
| Control | Two-position/three-position, relay contact 5 A, 250 V Continuous 0-4-20 mA 0-2-10 V | On-off, relay contact 5 A, 250 V |
| Control function | ON/OFF, P, PI, PD, PID, adjustable | ON/OFF, P, PI, PD, PID, adjustable, cascade control, ratio control adjustable |
| Alarms | 4 programmable alarms (absolute, relative, control, ...) | 4 programmable alarms (absolute, relative, control, ...) |
| Communication | Modbus RTU / 485 | ------------------------- |
| Data logging | USB stick / SD card | ------------------------- |
| Data | Data retained in E2 memory | Data retained in E2 memory |
Application examples
Documentation
01Technical documentation1