Screw-in thermometer for pipelines, boilers and tanks
TB
Screw-in thermometers for measuring the temperature of gases and liquids in pipelines under pressure or vacuum, from −50 to 600 °C. The measuring insert is replaced without opening the pipeline.
- Measuring range −50 to 600 °C, depending on version
- Pt100 to DIN EN 60751, Pt1000, type J or type K
- Connection head type B or F, aseptic version
- Thread G 1/2", G 1" or NPT 1/2"
- Optional 4–20 mA transmitter in the head and dual element
- Standard lengths 50 to 500 mm
Description
Type TB screw-in thermometers are intended for measuring the temperature of gases and liquids, most often in pipelines under pressure or vacuum. The measuring insert with transmitter can be replaced without opening the pipeline and without the medium escaping.
A dual measuring element and a 4–20 mA transmitter can be fitted in the thermometer head. The built-in Pt100 sensor is to DIN EN 60751; versions with Pt1000 and with an Fe-CuNi (type J) or Ni-CrNi (type K) thermocouple are also made.
The versions differ in the connection head (type B, type F or aseptic version for the food industry), with or without a neck. The protection tube is made of steel W.Nr. 1.4301 or 1.4571, and the process thread is G 1/2", G 1" or NPT 1/2". Standard lengths are 50 to 500 mm, depending on version.
Technical data
| Type | TB |
|---|---|
| Connection head | Type F Type B Aseptic version |
| Connection thread | G 1/2" G 1" NPT 1/2" |
| Measuring element | Pt100 Pt1000 FeCu-Ni [type J] Ni-CrNi [type K] |
| Protection tube | W.Nr.1.4301 Ø 10x1.5 mm W.Nr.1.4571 Ø 9x1 mm W.Nr.1.4571 Ø 11x2 mm ANSI 216 |
| Measuring range | 0 - 200 *C -50 - 400 *C -50 - 400/600 *C -50 - 200 *C |
| Standard lengths | 90-290 mm 50-250 mm 100-500 mm 100-460 mm |
Dimensions
The drawings are taken from the technical documentation.
Documentation
01Technical documentation2
02Brochures and catalogues1
From the same category
Temperature probes, thermometers and thermocouplesHelp with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection