Humidity and temperature transmitter up to 180 °C
MPRVT
Humidity and temperature transmitter in one housing, for chambers where both have to be measured. It measures relative humidity 0–100 % RH and temperature from −40 to 150 °C, and the sensor operates up to 180 °C.
- Humidity 0–100 % RH, temperature −40 to 150 °C
- Two 4–20 mA outputs, two-wire
- To order 0–20 mA or 0–10 V, four-wire
- Accuracy 2 % + 0.1 %/K for humidity, 0.5 % for temperature
- Housing 100 × 100 mm, IP 65, for wall or duct
- Sensor up to 180 °C, electronics 0–60 °C
Description
MPRVT converts relative humidity and temperature into a standard current signal. The humidity measuring range is 0–100 % RH and the temperature range −40 to 150 °C.
When both humidity and temperature have to be measured in a chamber, MPRVT combines both transmitters in one housing. It is used in industrial plants and chambers where humidity and temperature have to be controlled or monitored, most often in chambers for meat, fruit and vegetables and in incubators.
The sensor operates from −40 to 180 °C, and the electronics from 0 to 60 °C. The sensor holder for through-wall installation is made in lengths of 150, 250, 350 and 500 mm.
Technical data
| Type | MPRVT |
|---|---|
| Mounting | Wall mounting Duct mounting |
| Dimensions | 100x100 IP 65 |
| Input | Humidity and temperature |
| Operating temperature | -40 to +180 vC for sensor 0 to 60 ºC for electronics |
| Measuring range - humidity | 0-100 % rel. humidity |
| Measuring range - temperature | -40 to + 150ºC |
| Output | 4-20 mA -40-150ºC temperature 4-20 mA 0-100% humidity two-wire 0-20 mA, 0-10 V -40 -150ºC temperature 0-20 mA, 0-10V 0-100% rel. humidity four-wire [to order] |
| Accuracy | 2% + 0.1%/K for humidity 0.5% for temperature |
Dimensions
The drawings are taken from the technical documentation.
Documentation
01Technical documentation1
Help with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection