Ultrasonic level meter
ER-UK
Non-contact ultrasonic level meter with 4–20 mA output, powered from the current loop. The measuring range is up to 8 m or up to 11 m, depending on version.
- Measuring range 0.3–8 m or 0.45–11 m
- Loop-powered 12–30 VDC, output 4–20 mA
- LCD display (4 digits), setting by function keys
- Level, distance, volume and flow in open channels
- Housing IP 67 (NEMA 4), PVDF probe, connection 2" BSPT/NPT
- Versions with HART and with ATEX II 1 G EEx ia II T6 approval
Description
The ultrasonic level meter with indicator is intended for continuous level measurement with 4–20 mA output and is easy to install and set up. The MICROFLEX type meter is powered from the 4–20 mA signal loop, so no additional power supply is needed.
The meter has an LCD display showing the current level, and the parameters are set with function keys.
Functions:
- level measurement
- distance (height) measurement
- flow measurement in open channels
- volume measurement
- filtering
- setting of obstacles in the measuring path
It is used for level and volume measurement of powders (flour, sugar, salt, plastic granules, sand) and liquids (water, juices, oils, solvents, paints, waste water), and for flow measurement of waste water in open channels.
Technical data
Version comparison — swipe the table sideways on a phone.
| Property | MICROFLEX-C | MICROFLEX-C ER | MICROFLEX-C IS |
|---|---|---|---|
| Functionality | level or distance measurement | measurement of level, distance, volume, flow | measurement of level, distance, volume, flow |
| Measuring ranges | 0.3m to 8m / 1ft to 26ft | 0.45m to 11m / 1.5ft to 36ft | 0.45m to 11m / 1.5ft to 36ft |
| Protection | IP67 – NEMA 4 | IP67 – NEMA 4 | IP67 – NEMA 4 |
| Housing material | plastic | plastic | plastic |
| Power supply | 12 to 30 VDC – loop- powered | 12 to 30 VDC – loop- powered | 12 to 30 VDC – loop- powered |
| Analogue output | 4 – 20 mA | 4 – 20 mA | 4 – 20 mA |
| Impedance | maximum 750 ohm | maximum 750 ohm | maximum 750 ohm |
| Communication | — | HART | HART |
| Relay outputs | — | 2 x SPST 1A @ 24 VDC | — |
| Display | LCD (4-digit) | LCD (4-digit) | LCD (4-digit) |
| Electrical connection | 2 x M20 x 1.5mm | 2 x M20 x 1.5mm | 2 x M20 x 1.5mm |
| Probe material | PVDF | PVDF | PVDF |
| Process connection | 2" BSPT / NPT | 2" BSPT / NPT | 2" BSPT / NPT |
| Resolution | better than 1mm / 1/16" | better than 1mm / 1/16" | better than 1mm / 1/16" |
| Accuracy (of FS) | <1.0m ± 5mm >1.0m ± 1% | <1.0m ± 2.5mm >1.0m/3.3ft ± 0.25% | <1.0m ± 2.5mm >1.0m/3.3ft ± 0.25% |
| Damping | 1 – 99 seconds | 1 – 99 seconds | 1 – 99 seconds |
| Ambient temperature | -20°C to 70°C / -40°F to 158°F | -40°C to 60°C / -40°F to 140°F | -40°C to 60°C / -40°F to 140°F |
| Operating temperature | -20°C to 70°C / -40°F to 145°F | -30°C to 70°C / -22°F to 158°F | -30°C to 70°C / -22°F to 158°F |
| Operating pressure (max) | -0.25 to 3 bar / -3.6psi to 43psi max (20°C) | -0.25 to 3 bar / -3.6psi to 43psi max (20°C) | -0.25 to 3 bar / -3.6psi to 43psi max (20°C) |
| Beam angle | ± 6° (3db) | ± 6° (3db) | ± 6° (3db) |
| Electromagnetic compatibility | EN50081-1 & EN50082-2 | EN50081-1 & EN50082-2 | EN50081-1 & EN50082-2 |
| Maximum cable length | 3000m / 1.86 miles | 3000m / 1.86 miles | 3000m / 1.86 miles |
| Cable specification | 1 screened twisted pair | 1 screened twisted pair | 1 screened twisted pair |
| Weight | 850 g / 2 lbs | 850 g / 2 lbs | 850 g / 2 lbs |
| Approvals for hazardous areas | — | — | ATEX II 1 G EExia II T6 intrinsically safe, zone 0 |
Documentation
01Technical documentation1
Help with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection