Skip to content
Name, type or catalogue number

    Popular searches

    ↑↓ selectEnter open/ search from any page

    • ER-MINI

    Level switch with mini float

    ER-MINI

    Float level switch with one switching point, for vertical or horizontal (side) mounting. The reed contact is sealed in the tube and is not in contact with the liquid.

    Price from540,00 €+ VAT

    Catalogue number Float type
    Send an enquiry for this product
    • One switching point, volt-free reed contact
    • Mounting on the tank bottom or top, or on the side
    • Materials SUS304, SUS316, PP, PVDF, nylon, polysulphone
    • Pressure up to 30 bar, temperature up to 120 °C, depending on version
    • Contact NO, NC or changeover (SPDT)
    • 30 types of different dimensions and shapes

    Description

    The level switch with mini float is used for level signalling of liquids in reservoirs, tanks and boilers.

    The float contains a magnet that changes the state of a reed relay sealed in the tube, so the contact is not in contact with the liquid. The reed contact is volt-free and can be included in any signalling or control circuit.

    Application:

    • control of pumps and valves for level control
    • signalling of the liquid status to a monitoring system
    • minimum and maximum level signalling in hot-water boilers, cleaning equipment, tanks of hydraulic equipment, and water treatment equipment and plants

    We keep several float versions in stock.

    Technical data

    TypeER-MINI (30 types)
    Material0:SUS304
    6:SUS316
    PP
    PVDF
    NYLON
    POLYSUPHONE
    Mounting1.Tank bottom or top
    2.Side mounting
    Max. pressure [Bar]ATM, 4.5, 10, 30 bar
    Temperature [°C]-20 °C-80 °C
    -20 °C-100 °C
    -20 °C-120 °C
    Specific gravity [g/cm2]-0.5-1 g/cm2
    ContactD:50W 240Vac/200Vdc, SPST
    G:60W 220Vac, SPDT (use for tube >/=Ø12.7)
    K:20W 150Vac/200Vdc, SPDT
    Contact typeA:Normal Open (N.O.) SPST
    B:Normal Close (N.C.) SPST
    C:1AB SPDT

    Dimensions

    The drawings are taken from the technical documentation.

    Documentation

    Help with selection

    Describe your application and we will suggest a version and a catalogue number.

    For an accurate reply, please state in your enquiry:

    1. 01The medium and its temperature
    2. 02Measuring range
    3. 03Output signal or power supply
    4. 04Type of mounting and connection
    Enquiry forER-MINICat. no. EF
    Send an enquiry

    or contact us directly

    Mon – Fri, 7 am – 3 pm