Skip to content
Name, type or catalogue number

    Popular searches

    ↑↓ selectEnter open/ search from any page

    • MPN-KP — photo 1 of 2
    • MPN-KP — drawing 2 of 2

    Continuous level meter with float

    MPN-KP

    Continuous level meter for non-aggressive liquids, with a float on a stainless steel tube, in lengths from 200 to 2500 mm. The two-wire transmitter in the connection head is powered from the 4–20 mA loop.

    Price from150,00 €+ VAT

    Catalogue number Mounting connection
    Send an enquiry for this product
    • Lengths 200, 500, 750, 1000, 1500 and 2500 mm
    • Flange NP 16, DN 65, 80 or 100, or threaded connection
    • Operating pressure up to 16 bar, temperature up to 130 °C
    • Material in contact with the medium W.Nr. 1.4301
    • Output 4–20 mA, two-wire
    • Connection head IP 43 or IP 67
    ApplicationsLevel

    Description

    MPN-KP is intended for continuous level measurement of non-aggressive liquids (water, light oils, juices) in tanks and vessels at atmospheric or operating pressure.

    The body of the transmitter is a stainless steel tube (Ø10 or Ø12) along which a float moves, following the liquid level. Stops limit the float travel. At the top is a connection head containing the level transmitter.

    The transmitter is two-wire and is powered from the 4–20 mA signal loop. Only two terminals need to be connected for operation.

    Technical data

    TypeMPN-KP
    MountingFlange NP 16, DN 65, 80, 100, G2 "
    Length200, 500, 750, 1000, 1500, 2500 mm
    Length of measuring section100 mm
    Number of floats1
    Operating temperatureUp to 130 *C
    Material in contact with the mediumW.Nr. 1.4301
    Operating pressureUp to 16 bar
    Output4-20 mA two-wire
    Power supply24 VDC
    Connection headIP 43 / IP 67

    Dimensions

    The drawings are taken from the technical documentation.

    Application examples

    Documentation

    01Technical documentation1
    02Wiring diagrams and examples1

    Help with selection

    Describe your application and we will suggest a version and a catalogue number.

    For an accurate reply, please state in your enquiry:

    1. 01The medium and its temperature
    2. 02Measuring range
    3. 03Output signal or power supply
    4. 04Type of mounting and connection
    Enquiry forMPN-KPCat. no. 157
    Send an enquiry

    or contact us directly

    Mon – Fri, 7 am – 3 pm