    Measuring transmitter with galvanic isolation · New

    DRE-S

    Takes the signal from a sensor, displays it in measured units, passes it on with galvanic isolation to another device (PLC, recorder, controller) and signals when the value crosses a set limit.

    Price215,00 €+ VAT

    Send an enquiry for this product
    • Thermocouples J, K, L, S, R, T, N, E, B and resistance sensors Pt100/200, Ni100/200, Cu53
    • 0/4–20 mA, 0–50/60 mV and potentiometer inputs
    • 4-digit LED display
    • Galvanically isolated 0/4–20 mA or 0–10 V output
    • 4 alarms, 2 relays 250 VAC / 2 A
    • Option: 24 VDC / 40 mA sensor supply and Modbus RTU / RS485

    Description

    Takes the signal from a sensor, displays it in measured units, passes it on with galvanic isolation to another device (PLC, recorder, controller) and signals when the value crosses a set limit.

    Fields of application:

    • glass, plastics and ceramics processing
    • chemical industry
    • food industry
    • boiler manufacturing
    • mechanical engineering
    • heating and cooling technology
    • air conditioning

    Functions by application

    Swipe the table sideways on a phone.

    FunctionWhat the device doesApplication example
    Temperature measurementAccepts thermocouples (J, K, L, S, R, T, N, E, B) and resistance sensors (Pt100/200, Ni100/200, Cu53), with thermocouple cold-junction compensation.Temperature of a furnace, boiler, pipeline or coolant.
    Process signal measurementAccepts current (0/4–20 mA) and voltage (0–50/60 mV) signals and a potentiometer.Pressure, level or flow from another transmitter; valve or damper position.
    Display of the measured valueShows the value on a 4-digit LED display with 0–3 decimals, with scaling for current and voltage signals.Local reading on the cabinet, without an extra instrument.
    Signal conversion and retransmissionScales the measured value and sends it galvanically isolated as 0/4–20 mA or 0–10 V (also 2–10, 0–5, 1–5, 0–1, 0.2–1 V).A type K thermocouple converted to 4–20 mA for a PLC or for display on another device.
    Galvanic isolationSeparates the measuring circuit from the output, protecting the input from interference and ground loops.Measurement in a plant with several grounds or strong interference.
    Sensor supply (option)Provides 24 VDC / 40 mA to power a two-wire transmitter.Direct supply of a 4–20 mA pressure sensor.
    Alarms4 alarms (absolute minimum or maximum) with setpoint and hysteresis; each is assigned to relay 1 or 2 (250 VAC / 2 A).Switching on a siren or switching off a load on overheating.
    ON/OFF controlThe relay output switches a load on and off at the set limit with hysteresis.Simple temperature holding for a heater or fan.
    Remote monitoring (option)Modbus RTU / RS485 (slave): reading measured values and relay states, changing settings.Connection to a SCADA system or PLC.

    Help with selection

    Describe your application and we will suggest a version and a catalogue number.

    For an accurate reply, please state in your enquiry:

    1. 01The medium and its temperature
    2. 02Measuring range
    3. 03Output signal or power supply
    4. 04Type of mounting and connection
    Enquiry forDRE-S
    Send an enquiry

    or contact us directly

    Mon – Fri, 7 am – 3 pm