DIN rail controller · New
DRE-R
Measures a process variable on two inputs and holds it at the setpoint with PID or ON/OFF control, with alarms, a timer and digital inputs for external control.
- PID or ON/OFF control
- Heating and cooling, three-position motorised valve control
- Two programmable inputs: thermocouples, resistance sensors, current and voltage signals
- 4 alarms with 8 configurations
- Timer: on-delay, off-delay, astable operation
- Modbus RTU / RS485
Description
Measures a process variable on two inputs and holds it at the setpoint with PID or ON/OFF control, with alarms, a timer and digital inputs for external control.
Fields of application:
- glass, plastics and ceramics processing
- chemical industry
- food industry
- boiler manufacturing
- mechanical engineering
- heating and cooling technology
- air conditioning
Functions by application
Swipe the table sideways on a phone.
| Function | What the device does | Application example |
|---|---|---|
| PID control | All P, PI, PD and PID combinations; adjustable gain, integral and derivative time, control band and dead zone. | Precise furnace temperature control. |
| ON/OFF control | Switches the output on and off with adjustable hysteresis. | Simple tank temperature control. |
| Heating and cooling | Two-position or three-position operation: separate outputs for heating and cooling, reverse or direct action. | A climate chamber that heats and cools with the same controller. |
| Motorised valve control | Three-position control of a motorised valve (open, close, hold). | Mixing valve in a heating system. |
| Humidity and differential control | The controlled variable can be input 1, input 2, the difference of the inputs or psychrometric humidity. | Humidity control in a dryer or chamber. |
| Measurement on two inputs | Two programmable inputs: thermocouples, resistance sensors, current and voltage signals, potentiometer, psychrometer. | A temperature sensor and an additional signal on the same device. |
| Alarms | 4 alarms with 8 configurations: relative to the setpoint (± band, min, max) and absolute min/max; the source is input 1, input 2, the difference or humidity. | An alarm when the temperature deviates from the setpoint by more than allowed. |
| Timer | On-delay, off-delay and astable operation; times in seconds, minutes, hours or days. | Cyclic fan operation or delayed switch-on. |
| Remote monitoring | Modbus RTU / RS485 (slave). | Connection to a supervisory system. |
Help with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection