Address-alarm unit for up to 256 measuring points
EDPS-AP
Digital indicator with automatic switching and signalling of two limit values (MIN and MAX). Paired with EP-RS switching units, it measures and signals up to 256 measuring points.
Price from205,00 €+ VAT
Needed to operate
Works together with EP-RS switching units (16 input signals each).
- Up to 256 measuring points with EP-RS switching units
- Two alarms (MIN and MAX), volt-free contact, memory of the point where the limit was exceeded
- Manual or automatic cyclic switching, 1–255 s
- Inputs: 0/4–20 mA, voltage, Pt100, potentiometer, thermocouples J, K, S
- Display accuracy 0.5 %
- Housing 72 × 144 mm, optional RS-485 Modbus
Description
EDPS-AP paired with the EP-RS switching unit measures and signals up to 256 measuring points. It is used where a large number of signals must be monitored, for example on silos.
The analogue inputs are connected to the switching units. The alarm unit controls the switching units by a code and switches the channels, and on its display it shows the measured quantity and the measuring point currently being measured. On the switching unit an LED shows which channel is currently being measured.
The measuring points are divided into groups and subgroups. The front panel has four LED displays: two-digit displays for the group and the subgroup, a four-digit display for the measuring point and a four-digit display for the measured quantity.
The channels are switched manually, step by step, or automatically in a cycle with an adjustable time of 1 to 255 s. The cycle runs from the first to the last channel, and the last one need not be the 256th but the one you set.
Device functions:
- addressing of measuring points and display of the measured quantity
- setting of limit values, with hysteresis adjustable in magnitude and direction
- alarm via volt-free contact and memory of the point where the limit was exceeded
- defining the switching mode and speed
- review of alarm points
The input can be current (0–20 mA, 4–20 mA), voltage (0–50 mV, 0–1 V, 0–10 V, 2–10 V), resistance (Pt100, potentiometer) or a thermocouple J, K or S; other signals on special request. Power supply is 230 VAC, and RS-485 communication with the Modbus protocol is available as an option.
Technical data
| Type | EDPS-AP |
|---|---|
| Front panel | Membrane keypad |
| Mounting | Panel with cut-out |
| Housing | 72x144 mm |
| Power supply | 230 VAC |
| Display | 10mm green LED display, 2 digits, for the group 10mm green LED display, 2 digits, for the subgroup 10mm green LED display, 4 digits, for the measuring point 13mm red LED display, 4 digits, for the measured quantity |
| Input | Current - 0 - 20 mA, 4 - 20 mA Voltage - 0 - 50 mV, 0-1 V, 0-2-10 V Resistance - Pt100, potentiometers Thermocouples - J, K, S Other - on special request |
| Alarm | 2 alarms |
| Hysteresis | Adjustable in magnitude and direction |
| Function | Addressing of measuring points. Display of the measured quantity. Setting of limit values. Alarm (volt-free contact) and memory of the point where the measured quantity was exceeded. Defining the switching mode and speed (manually step by step or automatically in a cycle with a set timing). Review of alarm points (conditional). |
| Number of measuring points | 256 |
| Switching speed | 1 s to 255 s |
| Display accuracy | 0.5 % |
| Option | RS 485 communication MODBUS protocol |
Dimensions
The drawings are taken from the technical documentation.
Documentation
01Technical documentation1
From the same category
Indicators and alarm unitsHelp with selection
Describe your application and we will suggest a version and a catalogue number.
For an accurate reply, please state in your enquiry:
- 01The medium and its temperature
- 02Measuring range
- 03Output signal or power supply
- 04Type of mounting and connection